PCB leakage is easy to confirm but hard to locate. Resistance between two pins tells you leakage exists, yet the conductive path may be buried inside the laminate where visual inspection and surface analysis cannot reach.
A power supply board developed leakage in the field, initially confirmed between pin1 and pin2 of a small-board connector. A normal board of the same model powered at 220 VAC produced normal output; the failed board entered protection mode after about 5 minutes under a 35 A load, with no output voltage. After the housing was opened, obvious water marks were visible on the surface of the failed board. The leakage location had to be locked down electrically first; once surface checks came back clean, the search moved inside the laminate.
Method: The housings of the NG and OK samples were opened and examined under a stereo microscope.
Findings: Obvious water marks were present on the NG housing surface; no other visible anomaly was found.
Conclusion: The water marks are traces of a damp heat environment. Nothing on the surface directly explains the leakage, so the anomaly had to be sought further inside.
Method: Both boards were powered at 220 VAC and the voltages between connector pins were measured. The copper traces connecting pin1 and pin2 to the small board were then cut, 11.5 V was applied between pin1 and GND alone, and the voltage between pin1 and pin2 was measured again.
Findings:
Conclusion: The leakage occurs between pin1 and pin2 and is unrelated to the front-end circuitry of the small board.
Method: The pin1 and pin2 through-holes of the NG sample were examined by X-ray.
Findings: No obvious anomaly was found between the two through-holes.
Conclusion: X-ray projection cannot resolve finer internal defects, so the investigation continued.
Method: 11.5 V with a 5 mA current limit was applied to the pin1/pin2 circuit, and Thermal EMMI was used to collect the hotspot and locate the leakage.
Findings: The hotspot appeared between the pin1 and pin2 through-holes on the small board.
Conclusion: The leakage was localized between the two through-holes, confirming that current flows between pin1 and pin2.
Method: After Pt sputter coating for 30 s, the morphology between pin1 and pin2 was examined by SEM/EDS and the composition measured. The surface solder flux and conformal coating were then removed and the area re-examined.
Findings: No obvious morphological anomaly or leakage-related substance was found between the leaking through-holes. After removing the solder flux and conformal coating, no anomalous substance appeared between the through-holes either.
Conclusion: Surface causes were ruled out. The leakage path is not on the surface, leaving only the laminate interior; the next step was cross-sectioning.
Method: Samples were prepared by manual microsectioning per IPC-TM-650 2.1.1, ground down to the pin1/pin2 through-hole positions, and examined by metallurgical microscope and SEM with EDS composition measurement.
Findings:
Conclusion: Conductive anodic filament (CAF) was present between both pairs of through-holes. The filament is extremely fine: the CAF between pin1 and pin2 was lost during grinding, while the one between pin3 and pin4 happened to be exposed on the polished plane.
X-ray shows a projection image and SEM shows surface morphology; the CAF filament is hidden inside the glass-fiber gaps of the laminate, beyond the reach of both techniques. Electrical analysis, after cutting the copper traces connecting pin1 and pin2 to the small board and applying power separately, still measured 0.1742 V between pin1 and pin2, confirming the leakage was between those two pins. Hotspot localization then collected a hotspot between the two through-holes. Electrical methods locked down the position first, and cross-sectioning supplied the direct evidence of filament morphology and high Cu content.
Voids inside the glass fiber and resin gaps provide a migration path
↓
Under damp heat, copper dissolves anodically and ionizes
↓
The potential difference between pin1 and pin2 drives copper ion migration along the glass-fiber gaps
↓
Copper deposits in the path and grows into a metal filament connecting the two through-holes
↓
Resistance between the holes drops, leakage occurs, and the supply enters protection mode
The direct cause of the leakage on this power board is CAF between the pin1 and pin2 through-holes: the metal filament bridges the two holes, pulls the resistance down, and leakage follows. The filament between pin1 and pin2 was lost during grinding, so the direct morphological evidence comes from the CAF between pin3 and pin4 and the high Cu content in that region; electrical analysis and hotspot localization had already locked the leakage to pin1/pin2. The two lines of evidence support each other.
CAF formation requires four conditions: a potential difference provides the driving force for ion movement, a humid environment provides the medium for ionization, gaps inside the substrate such as resin and glass fiber provide the migration path, and metal ions provide the migrating species. Only when all four are met can a conductive filament grow. The water marks on the NG housing correspond to the humid-environment condition.
Disclaimer: This case has been desensitized. All data come from real laboratory analysis. Reproduction without permission is prohibited.